For architects and planners
Planning documents for a charging point
Station specifications, supply and placement requirements and sample text for tender documents. Drawings and the data sheet are available on request.

The directive (EU) 2024/1275 requires bike parking for at least 15% of average or 10% of total user capacity of non-residential buildings and 2 spaces per dwelling in residential buildings; for new buildings and major renovations it also wants ducting for later e-bike charging. National rules set the details. Plan a protected supply and a place for the station together with the bike spaces. EPBD requirements, calculator and checklist →
3D model
See the station from every side
Switch views, wall or stand mounting and accessories. A 175 cm figure shows the real scale.
Specifications
Powerbox in figures
Charging
- Outputs
- 6× DC + 2× ACDC for Powerbox cables, AC for original chargers
- DC output current
- 5× 4 A + 1× 10 Aup to 210 W per 4 A output
- Battery voltage
- 24 / 36 / 48 V
- Bike connection
- magnetic EnergyBus connectors to IEC14 cable types, 200 cm, under 200 g
- Management
- Powerbox.cloudaccess, monitoring, data for BMS
Installation
- Protection rating
- IP54indoors and outdoors
- Mounting
- wall or stand
- Certification
- European standards EN / IEC
- Dimensions (W × H × D)
- 480 × 497 × 236.4 mmper drawing 10/2026
- Weight
- in the data sheet, on request
- Power and recommended protection
- in the data sheet, on request
Placement
What to plan so the place passes inspection and satisfies the insurer
Electrical
- A separate circuit with its own protection
- A 30 mA residual current device (RCD)
- A central shut-off for the charging point
- By analogy with IEC/HD 60364-7-722 (charging point as a separate circuit)
Space
- Number of bike spaces under the applicable rules (EPBD: 15% of average / 10% of total capacity)
- Away from escape routes and sleeping areas
- A non-combustible surface and distance from combustibles
- Smoke or heat detection and a suitable extinguishing agent
- Outdoors at least IP54, ideally under a shelter
IEC/HD 60364-4-41, IEC/HD 60364-7-722, EN 15194, EN 50604-1, national fire safety standards; in Germany also VdS 3103.
Tender documents
Sample tender text
The text describes functional requirements. Adapt it to your project.
Charging station for e-bikes and light electric vehicles: – at least 6 DC charging outputs for 24/36/48 V batteries, of which at least 5 outputs at 4 A and 1 fast output at 10 A, – 2 AC sockets for original chargers, – bike connection with magnetic connectors to IEC (EnergyBus), cables for at least 14 connector types, – protection rating at least IP54, vandal-resistant construction, wall or stand mounting, – remote management: access control, monitoring of status and usage, data export, – compliance with European safety standards (EN / IEC), documentation for inspection.